rtp_engine: allocate RTP dynamic payloads per session
[asterisk/asterisk.git] / configs / samples / alarmreceiver.conf.sample
1 ;
2 ; alarmreceiver.conf
3 ;
4 ; Sample configuration file for the Asterisk alarm receiver application.
5 ;
6
7
8 [general]
9
10 ;
11 ; Specify a timestamp format for the metadata section of the event files
12 ; Default is %a %b %d, %Y @ %H:%M:%S %Z
13
14 timestampformat = %a %b %d, %Y @ %H:%M:%S %Z
15
16 ;
17 ; Specify a command to execute when the caller hangs up
18 ;
19 ; Default is none
20 ;
21
22 ;eventcmd = yourprogram -yourargs ...
23
24 ;
25 ; Specify a spool directory for the event files. This setting is required
26 ; if you want the app to be useful. Event files written to the spool
27 ; directory will be of the template event-XXXXXX, where XXXXXX is a random
28 ; and unique alphanumeric string.
29 ;
30 ; Default is none, and the events will be dropped on the floor.
31 ;
32
33 eventspooldir = /tmp
34
35 ;
36 ; The alarmreceiver app can either log the events one-at-a-time to individual
37 ; files in the spool directory, or it can store them until the caller
38 ; disconnects and write them all to one file.
39 ;
40 ; The default setting for logindividualevents is no.
41 ;
42
43 logindividualevents = no
44
45 ;
46 ; The timeout for receiving the first DTMF digit is adjustable from 1000 msec.
47 ; to 10000 msec. The default is 2000 msec. Note: if you wish to test the
48 ; receiver by entering digits manually, set this to a reasonable time out
49 ; like 10000 milliseconds.
50
51 fdtimeout = 2000
52
53 ;
54 ; The timeout for receiving subsequent DTMF digits is adjustable from
55 ; 110 msec. to 4000 msec. The default is 200 msec. Note: if you wish to test
56 ; the receiver by entering digits manually, set this to a reasonable time out
57 ; like 4000 milliseconds.
58 ;
59
60 sdtimeout = 200
61
62 ;
63 ; Wait for the connection to settle post-answer. Adjustable from 500 msec. to 10000 msec.
64 ; The default is 1250 msec.
65 ;
66
67 answait = 1250
68
69 ; When logging individual events it may be desirable to skip grouping of metadata
70
71 ;no_group_meta = yes
72
73 ;
74 ; The loudness of the ACK and Kissoff tones is adjustable from 100 to 8192.
75 ; The default is 8192. This shouldn't need to be messed with, but is included
76 ; just in case there are problems with signal levels.
77 ;
78
79 loudness = 8192
80
81 ;
82 ; The db-family setting allows the user to capture statistics on the number of
83 ; calls, and the errors the alarm receiver sees. The default is for no
84 ; db-family name to be defined and the database logging to be turned off.
85 ;
86
87 ;db-family = yourfamily:
88
89 ;
90 ; End of alarmreceiver.conf
91 ;