Merged revisions 250480 via svnmerge from
authorJeff Peeler <jpeeler@digium.com>
Wed, 3 Mar 2010 19:06:06 +0000 (19:06 +0000)
committerJeff Peeler <jpeeler@digium.com>
Wed, 3 Mar 2010 19:06:06 +0000 (19:06 +0000)
commite8a99a9962212fcc7b503e3e1ea42f9e2eed223b
tree237b67b20a4b97a537130e315b723caef7b7c0a9
parent59f615dbca77113a8137f3bc0bbd4eef5f16c0ce
Merged revisions 250480 via svnmerge from
https://origsvn.digium.com/svn/asterisk/branches/1.4

........
  r250480 | jpeeler | 2010-03-03 13:04:11 -0600 (Wed, 03 Mar 2010) | 15 lines

  Make sure to clear red alarm after polarity reversal.

  From the issue:
  The automatic overnight line tests (or manual ones) used on UK (BT) lines causes
  a red alarm on a dahdi / TDM400P connected channel. This is because the line
  uses voltage tests (battery loss) and polarity reversal. The polarity reversal
  causes chan_dahdi to initiate v23 CallerID processing but during this the event
  DAHDI_EVENT_NOALARM is ignored so that the alarm is never cleared.

  (closes issue #14163)
  Reported by: jedi98
  Patches:
        chan_dahdi-1.4-inalarm.diff uploaded by jedi98 (license 653)
  Tested by: mattbrown, Chainsaw, mikeeccleston
........

git-svn-id: https://origsvn.digium.com/svn/asterisk/trunk@250481 65c4cc65-6c06-0410-ace0-fbb531ad65f3
channels/chan_dahdi.c
channels/sig_analog.c