; backup1 is an optional list of backup d-channels.
;
;trunkgroup => 1,24,48
+;trunkgroup => 1,24
+ss7linkset = 1,24
;
; Spanmap: Associates a span with a trunk group
; spanmap => <zapspan>,<trunkgroup>[,<logicalspan>]
; 5ess: Lucent 5ESS
; euroisdn: EuroISDN
; ni1: Old National ISDN 1
+; qsig: Q.SIG
;
switchtype=national
;
; fxo_ks: FXO (Kewl Start)
; pri_cpe: PRI signalling, CPE side
; pri_net: PRI signalling, Network side
+; ss7: SS7 Signalling
; gr303fxoks_net: GR-303 Signalling, FXO Loopstart, Network side
; gr303fxsks_cpe: GR-303 Signalling, FXS Loopstart, CPE side
; sf: SF (Inband Tone) Signalling
signalling=fxo_ls
;
; For Feature Group D Tandem access, to set the default CIC and OZZ use
-; these parameters
+; these parameters:
;defaultozz=0000
;defaultcic=303
;
; channel => 1-23
;
+
+ss7link=1
+signalling = ss7
+channel => 1-23
+
; Used for distintive ring support for x100p.
; You can see the dringX patterns is to set any one of the dringXcontext fields
; and they will be printed on the console when an inbound call comes in.